70 CFM Ventilation Fan / Heater & Fluorescent Light
Model No. CBFVF70LH - Includes (1) 13 WATT PL Lamp
Bathrooms, Family Rooms, Bedrooms! |
• Includes (1) 13 Watt PL Lamp
• Includes Ballast
• Galvanized housing for humid conditions and
• various attic temperatures
• Built-in mounting tabs for quick installation
• Markings on housing for ceiling / wall thickness
• Built-in junction box for easy wiring
• Molded 4" duct adapter with built-in damper
• Built-in receptacle for quick activation
• Easy to remove and install motor assembly-key
• hole mounting bracket included
• Only 4.0 Sones
• 1100 watt heating element - fan forced
• Permanently lubricated motor with plug for quick
• activation
• Molded impeller and propeller-precision balanced
• for quiet operation
|
• Polycarbonate light lens-heat resistant with U.V. inhibitors and
• break-resistant materials and design
• Attractive molded grille
• Combo lamp compartment and reflector with built-in socket
• (CSA 100 Watt Max) - made of reflector-grade polished
• aluminum
|
DIMENSIONS
Housing: 13 1/4" x 7 3/4" x 5 3/4"
Grille: 12" x 17" |
|
|
 |
 |
Also Available in Incandescent (click for details)
 |
Only $59.99
Includes Fluorescent Bulb
DISCONTINUED
|
| Due to the low profit margin on this item we do not accept returns unless damaged or defective. Please refer to our terms of sale for complete details. |
INSTALLATION NOTES:
1) Attach duct adapter to housing, Align locking tabs on adapter with holes on housing, Snap into place.
2) Attach housing to joist with screws or nails. Housing is stamped to show 3/4" Standard Sheetrock / Plaster and 3/8"
2) Drywall, Adjust Accordingly.
3) Wire with 120VAC - 60Hz power leads, use the appropriate knock-out location on the housing and with an
3) appropriate wire connector (BX or Romex)
4) Remove outlet box cover by removing screw and pulling downward.
5) TURN OFF ELECTRICAL POWER AT SERVICE ENTRANCE!
6) Connect wire from wall switch to motor wires, and connect all remaining wires for light and heater. Use approved
6) wire connectors - white to white, black to black, and green to ground.
7) Replace outlet box cover and screw.
8) Install 4" duct to duct adapter and run to a roof jack or wall cap to ensure ventilation is ducted to the outside.
9) Install cover to housing with spring clips and or screw provided.
CAUTION: Be sure all wiring complies with local and national electric codes, and housing is properly grounded.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1) Must be installed on a separate 20 amp circuit and with 12 gauge wire
2) Ceiling installation ONLY - Maximum of 12/12 pitch and a minimum of 8" from any wall
3) Do NOT install in wall - This unit is ceiling installation only
4) Avoid directing heated air toward walls
5) Do NOT install in tub or shower enclosure
6) Do NOT use with any solid-state speed control device
7) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
8) Before servicing or cleaning this unit, switch power OFF at service panel and lock service panel to prevent power
8) from being switched on accidentally. If the service panel cannot be locked, fasten a prominent warning device to
8) the service panel (such as a tag).
9) Installation and all electrical wiring must be done by qualified person(s) in accordance with all applicable codes
9) and standards, including fire-rated construction codes and standards.
10) When cutting or drilling into a wall or ceiling, do NOT damage electrical wiring or other hidden utilities.
11) Ducted fans MUST ALWAYS be vented to outdoors.
12) Never install or place a switch where it can be reached from a tub or shower.
13) NOT for use in kitchens
14) NOT for use with heating equipment, fuel burning equipment or chimneys.
15) This unit MUST be grounded.
16) Keep drywall spray and construction dirt off motor assembly to avoid bearing damage and/or unbalanced
16) impellars. |
|
|